dvp14ss211t
plc modbus rtu rs485/422 communicate module DVPSCM52-SL
  • Functional device:RS-485/ RS-422 communication module which support BACNet protocols​
  • Input voltage:DC+24V
  • Applicable PLC host:DVP-SS2;DVP-SA2;DVP-SX2;DVP-SE;DVP-SV2
  • Communication Interface:2 RS-485 ; 2 RS-422
  • Function:Add 2 RS485 & 2 RS422 communication interface for system
dvp14ss211t
delta plc rs485/rs422 communication module DVPSCM12-SL
  • Functional device:RS-485/ RS-422 communication module
  • Function:Add 2 RS485 & 2 RS422 communication interface for system.
  • Applicable PLC host:DVP-SS2;DVP-SA2;DVP-SX2;DVP-SE;DVP-SV2
  • Communication Interface:2 RS-485 ; 2 RS-422
dvp14ss211t
delta slime plc profibus communication slaves module DVPPF02-SL
  • Functional device:Profibus communication module
  • Input voltage:DC+24V
  • Applicable PLC host:DVP-SS2;DVP-SA2;DVP-SX2;DVP-SE;DVP-SV2
  • Communication Interface:1 Profibus port
  • Function:Add 1 Profibus communication slaves interface for system
dvpcopm sl
Delta slim plc can bus slaves communication module DVPCOPM-SL
  • Functional device:CANopen communication module
  • Input voltage:DC +24V
  • Applicable PLC host:DVP-SS2;DVP-SA2;DVP-SX2;DVP-SE;DVP-SV2
  • Communication Interface:1 CANopen port
  • Function:Add 1 CANopen communication interface for system
dvp14ss211t
delta slim devicenet plc host communication expand module DVPDNET-SL
  • Functional device:DeviceNet communication module
  • Input voltage:DC +24V
  • Applicable PLC host:DVP-SS2;DVP-SA2;DVP-SX2;DVP-SE;DVP-SV2
  • Communication Interface:1 DeviceNet port
  • Function:Add 1 DeviceNet host communication interface for system
dvp14ss211t
delta plc ethernet communication host expand module DVPEN01-SL
  • Functional device:Ethernet communication module
  • Input voltage:DC +24V
  • Applicable PLC host:DVP-SS2;DVP-SA2;DVP-SX2;DVP-SE;DVP-SV2
  • Communication Interface:1 RS-232 ; 1 Ethernet
  • Function:Add 1 Ethernet communication interface for system
dvp28sv11t2
16 input 12 output delta high speed output pwm plc DVP28SV11T2
  • Series:Delta DVP SV2
  • Input voltage:DC 24V
  • Functional device:Basic PLC
  • Output Type:Transistor (NPN)
  • Number of Input:16
  • Number of Output:12
  • Maximum I/O Expansions:480
  • High-speed pulse output:6 points of 200 kHz;6 points of 10 kHz
  • Communication Interface:1 RS-232 ; 1 RS-485
  • High-speed counters input:200 kHz / 8 points ,10 kHz / 8 points
dvp14ss211t
High speed output motion plc for servo motor control DVP28SV11S2
  • Series:Delta DVP SV2
  • Input voltage:DC 24V
  • Functional device:Basic PLC
  • Output Type: Transistor (PNP)
  • Number of Input:16
  • Number of Output:12
  • Maximum I/O Expansions:480
  • High-speed pulse output:6 points of 200 kHz;6 points of 10 kHz
  • Communication Interface:1 RS-232 ; 1 RS-485
  • High-speed counters input:200 kHz / 8 points ,10 kHz / 8 points
dvp14ss211t
high speed counter plc use for rotary encoder DVP28SV11R2
  • Series:Delta DVP SV2
  • Input voltage:DC 24V
  • Functional device:Basic PLC
  • Output Type:Relay
  • Number of Input:16
  • Number of Output:12
  • Maximum I/O Expansions:480
  • High-speed pulse output:Without
  • Communication Interface:1 RS-232 ; 1 RS-485
  • High-speed counters input:200 kHz / 8 points ,10 kHz / 8 points
dvp14ss211t
14 input 12 output delta plc with ethernet communication port DVP26SE11T
  • Series:Delta DVP SE
  • Input voltage:DC 24V
  • Functional device:Basic PLC
  • Output Type: Transistor (NPN)
  • Number of Input:14
  • Number of Output:12
  • Maximum I/O Expansions:480
  • High-speed pulse output:100 kHz / 2 points, 10 kHz / 2 points
  • Communication Interface: 2 RS-485;1 mini usb;1 Ethernet
  • High-speed counters input:100 kHz / 3 points, 10 kHz / 5 points